<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>FIB Archives - Laser Micromachining - 3D-Micromac AG</title>
	<atom:link href="https://3d-micromac.de/tag/fib/feed/" rel="self" type="application/rss+xml" />
	<link>https://3d-micromac.de/tag/fib/</link>
	<description></description>
	<lastBuildDate>Mon, 06 Oct 2025 12:25:04 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.9</generator>

<image>
	<url>https://3d-micromac.com/wp-content/uploads/2016/03/favicon.png</url>
	<title>FIB Archives - Laser Micromachining - 3D-Micromac AG</title>
	<link>https://3d-micromac.de/tag/fib/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>3D-Micromac verkürzt die Vorbereitungszeit für die Atomsondentomographie von Stunden auf Minuten mit neuen Lasermicrobearbeitungssystem microPREP PRO FEMTO</title>
		<link>https://3d-micromac.de/3d-micromac-verkuerzt-die-vorbereitungszeit-fuer-die-atomsondentomographie-von-stunden-auf-minuten-mit-neuen-lasermicrobearbeitungssystem-microprep-pro-femto/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 12 Apr 2023 13:49:19 +0000</pubDate>
				<category><![CDATA[News]]></category>
		<category><![CDATA[News Startseite]]></category>
		<category><![CDATA[Atom Probe Tomography]]></category>
		<category><![CDATA[cylindrical samples]]></category>
		<category><![CDATA[failure analysis]]></category>
		<category><![CDATA[FIB]]></category>
		<category><![CDATA[laser micromachining]]></category>
		<category><![CDATA[laser-based sample preparation]]></category>
		<category><![CDATA[microPREP PRO]]></category>
		<category><![CDATA[Sample preparation]]></category>
		<guid isPermaLink="false">https://3d-micromac.com/?p=19437</guid>

					<description><![CDATA[<p>Die microPREP™ PRO FEMTO ermöglicht einen mikrometergenauen Materialabtrag bei erheblich höheren Geschwindigkeiten als beim FIB-Abtrag und vermeidet dabei thermische Schäden an der Probe.</p>
<p>The post <a rel="nofollow" href="https://3d-micromac.de/3d-micromac-verkuerzt-die-vorbereitungszeit-fuer-die-atomsondentomographie-von-stunden-auf-minuten-mit-neuen-lasermicrobearbeitungssystem-microprep-pro-femto/">3D-Micromac verkürzt die Vorbereitungszeit für die Atomsondentomographie von Stunden auf Minuten mit neuen Lasermicrobearbeitungssystem microPREP PRO FEMTO</a> appeared first on <a rel="nofollow" href="https://3d-micromac.de">Laser Micromachining - 3D-Micromac AG</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="flex_column av_one_full  flex_column_div av-zero-column-padding first  avia-builder-el-0  el_before_av_two_third  avia-builder-el-first  " style='border-radius:0px; '><p><div  style='padding-bottom:10px; ' class='av-special-heading av-special-heading-h1    avia-builder-el-1  el_before_av_heading  avia-builder-el-first  '><h1 class='av-special-heading-tag '  itemprop="headline"  >3D-Micromac verkürzt mit neuem Lasermikrobearbeitungssystem die Vorbereitungszeit für die Atomsondentomographie von Stunden auf Minuten</h1><div class='special-heading-border'><div class='special-heading-inner-border' ></div></div></div><br />
<div  style='padding-bottom:10px; ' class='av-special-heading av-special-heading-h2    avia-builder-el-2  el_after_av_heading  avia-builder-el-last  '><h2 class='av-special-heading-tag '  itemprop="headline"  >Die microPREP™ PRO FEMTO ermöglicht einen mikrometergenauen Materialabtrag bei erheblich höheren Geschwindigkeiten als beim FIB-Abtrag und vermeidet dabei thermische Schäden an der Probe </h2><div class='special-heading-border'><div class='special-heading-inner-border' ></div></div></div></p></div>
<div class="flex_column av_two_third  flex_column_div av-zero-column-padding first  avia-builder-el-3  el_after_av_one_full  el_before_av_one_third  column-top-margin" style='border-radius:0px; '><section class="av_textblock_section "  itemscope="itemscope" itemtype="https://schema.org/BlogPosting" itemprop="blogPost" ><div class='avia_textblock  '   itemprop="text" ><p><strong>Chemnitz, Deutschland, 12. April, 2023</strong>—Die 3D-Micromac AG, führender Anbieter von Lasermikrobearbeitungs- und Rolle-zu-Rolle-Lasersystemen für die Halbleiter-, Photovoltaik-, Glas- und Displayindustrie, stellte heute das Lasermikrobearbeitungssystem microPREP PRO FEMTO für die Hochgeschwindigkeits-Atomsondentomographie (APT) und Querschnittsprobenvorbereitung vor.</p>
<p>Das microPREP PRO FEMTO-System deckt einen wesentlichen Bedarf in der Materialanalyse auf atomarer Ebene. Mit dem integrierten Femtosekundenlaser und einem optimiertem optischen Aufbau ermöglicht das System eine mikrometergenaue Materialentfernung in wenigen Minuten anstatt vieler Stunden mit fokussiertem Ionenstrahl-Abtrag. Gleichzeitig werden mechanische und thermische Schäden an der Probe vermieden. Die microPREP PRO FEMTO erlaubt die Herstellung von APT-Mikroproben direkt aus dem Probenmaterial mithilfe automatisierter Workflows. Die dadurch frei werdenden FIB-Ressourcen können somit für abschließende Präparationsschritte verwendet werden, wie zum Beispiel das finale Fräsen und Polieren der Mikrospitzen.</p>
<p>Das Department Werkstoffwissenschaft der Montanuniversität Leoben, ein führendes Forschungsinstitut in den Bereichen Bergbau, Metallurgie und Materialwissenschaften, hat das erste microPREP PRO FEMTO-System gekauft und nutzt es für die Präparation von APT-Proben unterschiedlichster Materialien. Dr. Michael Tkadletz, Lehrstuhl für Funktionelle Materialien und Materialsysteme an der Montanuniversität Leoben, sagt: „APT ist eine entscheidende Technik für die wissensbasierte Entwicklung moderner Hochleistungswerkstoffe. Sie kann beispielsweise dazu beitragen, die Segregation von Verunreinigungen und Begleitelementen an Korngrenzen von ‚Grünen Stählen‘ zu untersuchen, die komplexe Elementverteilung innerhalb multifunktionaler Beschichtungen und Nanostrukturen aufzudecken oder die Auswirkungen lokaler chemischer Fluktuationen auf die Leistung von Materialien zur Energiespeicherung und –umwandlung zu untersuchen. Der größte Engpass für APT-Experimente ist jedoch die aufwändige und zeitraubende Probenvorbereitung. Die Femtosekundenlaser-Präparation mit der microPREP PRO FEMTO hilft, diesen Engpass zu überwinden, indem sie die Komplexität der Prozesse deutlich reduziert. Zugleich wird die Zeit bis zur fertigen Probe und die Nutzung des FIB deutlich verringert, während gleichzeitig die Anzahl der präparierten Proben im Vergleich zu einem Standard-Lift-Out-Verfahren erheblich gesteigert werden kann.”</p>
<p><strong>Neue Ansätze für die APT-Probenvorbereitung </strong></p>
<p>Herkömmlicherweise basieren APT-Probenvorbereitungsprozesse auf elektrolytischen oder ionenbasierten Workflows zum Abdünnen des Materials. Beide Arbeitsabläufe erfordern mechanische Vorbereitungsschritte, die die Probe mechanisch belasten, was sich auf die Gesamtqualität und das Ergebnis auswirken kann. Die Verwendung des FIB-Abtrags für den Präparationsprozess zur Vermeidung mechanischer Belastungen kann viele Stunden dauern und erfordert ein Herausheben der Probe, welches das Risiko einer Beschädigung mit sich bringt. Da FIB-Systeme kostspielig sind, bindet dieser Ansatz auch FIB-Ressourcen, die mit sehr hohen Betriebskosten für den Benutzer verbunden sind.</p>
<p>Einige Systeme kombinieren einen Laser für die Hochgeschwindigkeitsablation und einen FIB-Laser für die Endpolitur in einer einzelnen Plattform. Jedoch führt auch dieser Ansatz zu Kapazitätsengpässen, da immer nur ein Prozess genutzt werden kann. Da die Laservorbereitung große Materialmengen abträgt, wird außerdem die Partikelkontamination im Analysebereich von kombinierten Laser-/FIB-Werkzeugen zu einem größeren Problem. Die Entfernung der Partikel ist aufgrund der Vakuumbedingungen innerhalb der Prozesskammer schwierig. Kurzpulslaser können zudem große Wärmeeinflusszonen verursachen, die nicht nur die Probe beschädigen, sondern auch die Struktur der Probenspitzen verändern und so zu ungenauen Messergebnissen führen.</p>
<p><strong>Dedizierte Femtosekundenlaser-Mikrobearbeitung</strong></p>
<p>Im Gegensatz zu diesen anderen Ansätzen ist die microPREP PRO FEMTO eine dedizierte Lasermikrobearbeitungslösung, welche einen Femtosekundenlaser verwendet, um die hohe Geschwindigkeit, Genauigkeit, Kosteneffizienz und Vielseitigkeit zu bieten, die Forschungslabore und Universitäten für die APT-Probenvorbereitung und Querschnittsanalyse benötigen.</p>
<p>Die microPREP PRO FEMTO kann Proben präparieren, die nur bis zu zwei Mikrometer von der finalen Probengeometrie entfernt sind. Dadurch verringert sich die APT-Probenvorbereitungszeit im Vergleich zum reinen FIB-Abtrag von vielen Stunden auf nur wenige Minuten. Die Nutzung eines Femtosekundenlasers begrenzt die dabei entstehende Wärmeeinflusszone im Material auf wenige Nanometer im Vergleich zur Wärmeeinflusszone, die bei der Bearbeitung mit Pikosekundenlasern im Submikrometerbereich liegen kann. Zudem verfügt die microPREP PRO FEMTO über einen optimierten optischen Aufbau: Ein telezentrisches Objektiv ermöglicht eine höhere Präzision bei der Herstellung von APT-Mikrospitzen. Dies ist besonders wichtig für Probenfelder mit vielen APT-Säulen. Eine kurze Brennweite und ein kleiner Laserspot tragen ebenfalls zu höchster Präzision bei.</p>
<p>Zusätzlich ist die microPREP PRO FEMTO mit einem integrierten CO<sub>2 </sub>Reinigungssystem ausgestattet, welches kontaktlos mit Druckluft und Trockeneis in normaler Atmosphäre arbeitet, um Partikel nach dem Laservorbereitungsprozess sicher von der Oberfläche zu entfernen.</p>
<p>Mehrere vordefinierte Workflows für eine Vielzahl von Anwendungsfällen erleichtern die Einrichtung und den Betrieb der microPREP PRO FEMTO zusätzlich.</p>
<p>„Da die Materialwissenschaft immer tiefer in den Sub-Nanometer- und atomaren Bereich vordringt, wächst die Nachfrage nach Atomsonden-Tomographie für hochauflösende und auf 3D-Bildgebung basierende Materialanalysen weiter. Die Vorfertigung von Mikrospitzen-Arrays für die APT-Probenpräparation unter Verwendung eines speziellen Femtosekunden-Laserablationssystems kann im Vergleich zu mechanischem Sägen, Fräsen oder Kurzpulslaserablation enorme Zeit- und Kosteneinsparungen mit sich bringen”, sagte Dr. Boris Arnold Rottwinkel, Produktmanager Mikrodiagnostik bei 3D-Micromac. „Durch unsere langjährige Expertise in der Lasermikrobearbeitung sowie bei der laserbasierten Probenvorbereitung kann 3D-Micromac mit der neuen microPREP PRO FEMTO Forschungslaboren und Universitäten einen äußerst günstigen, skalierbaren und vielseitigen Ansatz für die APT-spezifische Präparation anbieten, um deren wachsenden und anspruchsvolleren Bedarf an die Materialanalyse zu erfüllen.”</p>
<p>3D-Micromac wird die neue microPREP PRO FEMTO auf mehreren führenden internationalen Messen und Konferenzen zum Thema Mikroskopie präsentieren, unter anderem auf der Microscopy and Microanalysis (M&amp;M) 2023 in Minneapolis, USA, der IMC’20 in Busan, Korea, und der ISTFA 2023 in Phoenix, USA.</p>
<p>Darüber hinaus wird Dr. Tkadletz von der Montanuniversität Leoben auf der 57. Metallographie-Konferenz (ASMET) in Leoben und auf dem 93. IUVSTA-Workshop in Seggau über die Vorteile der Verwendung der microPREP PRO FEMTO sprechen.</p>
<p>Weitere Informationen zur microPREP PRO FEMTO sind auf unserer englischsprachigen Webseite <a href="http://www.microPREP.pro">www.microPREP.pro</a> zu finden.</p>
</div></section></div>
<div class="flex_column av_one_third  flex_column_div av-zero-column-padding   avia-builder-el-5  el_after_av_two_third  el_before_av_one_full  column-top-margin" style='border-radius:0px; '><p><div  class='avia-image-container  av-styling-    avia-builder-el-6  el_before_av_textblock  avia-builder-el-first  avia-align-center '  itemprop="image" itemscope="itemscope" itemtype="https://schema.org/ImageObject"  ><div class='avia-image-container-inner'><div class='avia-image-overlay-wrap'><img decoding="async" class='wp-image-19425 avia-img-lazy-loading-not-19425 avia_image' src="https://3d-micromac.com/wp-content/uploads/2023/04/microPRO_PRO_FEMTO_web.jpg" alt='Rendering of the microPREP PRO FEMTO system' title='Rendering microPRO PRO FEMTO' height="900" width="888"  itemprop="thumbnailUrl" srcset="https://3d-micromac.com/wp-content/uploads/2023/04/microPRO_PRO_FEMTO_web.jpg 888w, https://3d-micromac.com/wp-content/uploads/2023/04/microPRO_PRO_FEMTO_web-296x300.jpg 296w, https://3d-micromac.com/wp-content/uploads/2023/04/microPRO_PRO_FEMTO_web-80x80.jpg 80w, https://3d-micromac.com/wp-content/uploads/2023/04/microPRO_PRO_FEMTO_web-768x778.jpg 768w, https://3d-micromac.com/wp-content/uploads/2023/04/microPRO_PRO_FEMTO_web-36x36.jpg 36w, https://3d-micromac.com/wp-content/uploads/2023/04/microPRO_PRO_FEMTO_web-696x705.jpg 696w" sizes="(max-width: 888px) 100vw, 888px" /></div></div></div><br />
<section class="av_textblock_section "  itemscope="itemscope" itemtype="https://schema.org/BlogPosting" itemprop="blogPost" ><div class='avia_textblock  '   itemprop="text" ><p><em>Das microPREP™ PRO FEMTO Lasermikrobearbeitungssystem für Hochgeschwindigkeits-Atomsondentomographie (APT) und Querschnittsprobenvorbereitung.</em></p>
</div></section><br />
<div  class='avia-image-container  av-styling-    avia-builder-el-8  el_after_av_textblock  el_before_av_textblock  avia-align-center '  itemprop="image" itemscope="itemscope" itemtype="https://schema.org/ImageObject"  ><div class='avia-image-container-inner'><div class='avia-image-overlay-wrap'><img decoding="async" class='wp-image-19423 avia-img-lazy-loading-not-19423 avia_image' src="https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_005_web.jpg" alt='SEM image of the processed Titanium Nitride on Silicon microtip arrays prepared by microPREP® PRO FEMTO directly from the specimen' title='SEM image of the processed Titanium Nitride on Silicon microtip arrays prepared by microPREP® PRO FEMTO directly from the specimen' height="574" width="800"  itemprop="thumbnailUrl" srcset="https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_005_web.jpg 800w, https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_005_web-300x215.jpg 300w, https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_005_web-768x551.jpg 768w, https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_005_web-705x506.jpg 705w" sizes="(max-width: 800px) 100vw, 800px" /></div></div></div><br />
<section class="av_textblock_section "  itemscope="itemscope" itemtype="https://schema.org/BlogPosting" itemprop="blogPost" ><div class='avia_textblock  '   itemprop="text" ><p><em>REM-Aufnahme von mit der microPREP PRO FEMTO bearbeiteten Titaniumnitrid-Silizium-Mikrospitzen-Arrays. (Bildquelle: Universität Leoben)</em></p>
</div></section><br />
<div  class='avia-image-container  av-styling-    avia-builder-el-10  el_after_av_textblock  el_before_av_textblock  avia-align-center '  itemprop="image" itemscope="itemscope" itemtype="https://schema.org/ImageObject"  ><div class='avia-image-container-inner'><div class='avia-image-overlay-wrap'><img decoding="async" class='wp-image-19424 avia-img-lazy-loading-not-19424 avia_image' src="https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_008_web.jpg" alt='Detailed view of processed Titanium Nitride microtip' title='Detailed view of processed Titanium Nitride microtip' height="574" width="800"  itemprop="thumbnailUrl" srcset="https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_008_web.jpg 800w, https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_008_web-300x215.jpg 300w, https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_008_web-768x551.jpg 768w, https://3d-micromac.com/wp-content/uploads/2023/04/TiNonSi_AuCap_008_web-705x506.jpg 705w" sizes="(max-width: 800px) 100vw, 800px" /></div></div></div><br />
<section class="av_textblock_section "  itemscope="itemscope" itemtype="https://schema.org/BlogPosting" itemprop="blogPost" ><div class='avia_textblock  '   itemprop="text" ><p><em>REM-Detailaufnahme von mit der microPREP PRO FEMTO bearbeiteten Titaniumnitrid-Silizium-Mikrospitzen. (Bildquelle: Universität Leoben)</em></p>
</div></section></p></div>
<div class="flex_column av_one_full  flex_column_div av-zero-column-padding first  avia-builder-el-12  el_after_av_one_third  avia-builder-el-last  column-top-margin" style='border-radius:0px; '><section class="av_textblock_section "  itemscope="itemscope" itemtype="https://schema.org/BlogPosting" itemprop="blogPost" ><div class='avia_textblock  '   itemprop="text" ><p><strong>Über die 3D-Micromac AG</strong></p>
<p>Die im Jahr 2002 gegründete 3D-Micromac AG ist der führende Spezialist für Lasermikrobearbeitung. Das Unternehmen steht für leistungsfähige, anwenderfreundliche und zukunftsorientierte Prozesse mit größter Produktionseffizienz.</p>
<p>3D-Micromac entwickelt Verfahren, Maschinen und komplette Anlagen auf höchstem technischen und technologischen Niveau. Die Systeme kommen in vielen Hightech-Branchen weltweit erfolgreich zum Einsatz, zum Beispiel in der Photovoltaik-, Halbleiter-, Glas- und Display-Industrie als auch in der Mikrodiagnostik und der Medizintechnik.</p>
</div></section></div>
<!----><p>The post <a rel="nofollow" href="https://3d-micromac.de/3d-micromac-verkuerzt-die-vorbereitungszeit-fuer-die-atomsondentomographie-von-stunden-auf-minuten-mit-neuen-lasermicrobearbeitungssystem-microprep-pro-femto/">3D-Micromac verkürzt die Vorbereitungszeit für die Atomsondentomographie von Stunden auf Minuten mit neuen Lasermicrobearbeitungssystem microPREP PRO FEMTO</a> appeared first on <a rel="nofollow" href="https://3d-micromac.de">Laser Micromachining - 3D-Micromac AG</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lab (r)evolution &#8211; Best practice for laser-based sample preparation</title>
		<link>https://3d-micromac.de/lab-revolution-laser-based-sample-preparation/</link>
		
		<dc:creator><![CDATA[Claudia Radelow]]></dc:creator>
		<pubDate>Wed, 07 Oct 2020 09:01:19 +0000</pubDate>
				<category><![CDATA[Webinaraufnahmen]]></category>
		<category><![CDATA[FIB]]></category>
		<category><![CDATA[laser-based sample preparation]]></category>
		<category><![CDATA[microPREP PRO]]></category>
		<category><![CDATA[Sample preparation]]></category>
		<guid isPermaLink="false">https://3d-micromac.com/?p=15423</guid>

					<description><![CDATA[<p>This free webinar will give you deep insights on the advantages of laser based sample preparation with microPREP™ PRO.</p>
<p>The post <a rel="nofollow" href="https://3d-micromac.de/lab-revolution-laser-based-sample-preparation/">Lab (r)evolution &#8211; Best practice for laser-based sample preparation</a> appeared first on <a rel="nofollow" href="https://3d-micromac.de">Laser Micromachining - 3D-Micromac AG</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="flex_column av_two_third  flex_column_div av-zero-column-padding first  avia-builder-el-0  el_before_av_one_third  avia-builder-el-first  " style='border-radius:0px; '><section class="av_textblock_section "  itemscope="itemscope" itemtype="https://schema.org/BlogPosting" itemprop="blogPost" ><div class='avia_textblock  '   itemprop="text" ><h1>Lab (r)evolution &#8211; Best practice for laser-based sample preparation</h1>
</div></section><br />
<section class="av_textblock_section "  itemscope="itemscope" itemtype="https://schema.org/BlogPosting" itemprop="blogPost" ><div class='avia_textblock  '   itemprop="text" ><p>Watch now our  <strong>free webinar ”Lab (r)evolution &#8211; Best practice for laser-based sample preparation&#8220;.</strong></p>
<p>This webinar covers the following topics:</p>
<p>• Basics of laser-based preparation of different materials<br />
• Reasons for laser-based sample preparation<br />
• Laser-based sample preparation with microPREP™ PRO: Stages and Fixtures<br />
• microPREP™ PRO vs. other methods of sample preparation for FIB &amp; Co.</p>
</div></section><br />
<div  class='avia-button-wrap avia-button-center  avia-builder-el-3  el_after_av_textblock  avia-builder-el-last ' ><a href='https://attendee.gotowebinar.com/register/641418110182034699?source=Webseite' class='avia-button  avia-color-theme-color-highlight   avia-icon_select-yes-left-icon avia-size-small avia-position-center ' target="_blank" rel="noopener noreferrer"><span class='avia_button_icon avia_button_icon_left ' aria-hidden='true' data-av_icon='' data-av_iconfont='entypo-fontello'></span><span class='avia_iconbox_title' >Watch the recording now!</span></a></div></p></div><div class="flex_column av_one_third  flex_column_div av-zero-column-padding   avia-builder-el-4  el_after_av_two_third  el_before_av_promobox  " style='border-radius:0px; '><div  class='avia-image-container  av-styling-    avia-builder-el-5  avia-builder-el-no-sibling  avia-align-center '  itemprop="image" itemscope="itemscope" itemtype="https://schema.org/ImageObject"  ><div class='avia-image-container-inner'><div class='avia-image-overlay-wrap'><img decoding="async" class='wp-image-14148 avia-img-lazy-loading-not-14148 avia_image' src="https://3d-micromac.com/wp-content/uploads/2020/03/microPREP_PRO_02_web-733x1030.png" alt='microPREP PRO' title='microPREP_PRO' height="1030" width="733"  itemprop="thumbnailUrl" srcset="https://3d-micromac.com/wp-content/uploads/2020/03/microPREP_PRO_02_web-733x1030.png 733w, https://3d-micromac.com/wp-content/uploads/2020/03/microPREP_PRO_02_web-214x300.png 214w, https://3d-micromac.com/wp-content/uploads/2020/03/microPREP_PRO_02_web-768x1079.png 768w, https://3d-micromac.com/wp-content/uploads/2020/03/microPREP_PRO_02_web-502x705.png 502w, https://3d-micromac.com/wp-content/uploads/2020/03/microPREP_PRO_02_web-450x632.png 450w, https://3d-micromac.com/wp-content/uploads/2020/03/microPREP_PRO_02_web.png 822w" sizes="(max-width: 733px) 100vw, 733px" /></div></div></div></div></p>
	<div   class='av_promobox  avia-button-yes   avia-builder-el-6  el_after_av_one_third  avia-builder-el-last '>		<div class='avia-promocontent'></p>
<h3>Keep up with the news from 3D-Micromac!</h3>
<p>Receive early access to our webinars, whitepapers and case studies. Don’t miss any events, special offers or updates to our products.</p>
<div id="__kantu_mark__"></div>
<div id="__kantu_mark__"></div>
<div id="__kantu_mark__"></div>
<div id="__kantu_mark__"></div>
<div id="__kantu_mark__"></div>
<p>
</div><div  class='avia-button-wrap avia-button-right ' ><a href='https://3d-micromac.com/laser-micromachining/news/newsletter/'  class='avia-button  avia-color-theme-color   avia-icon_select-yes-left-icon avia-size-large avia-position-right '   ><span class='avia_button_icon avia_button_icon_left ' aria-hidden='true' data-av_icon='' data-av_iconfont='entypo-fontello'></span><span class='avia_iconbox_title' >Subscribe now!</span></a></div></div>
<!----><p>The post <a rel="nofollow" href="https://3d-micromac.de/lab-revolution-laser-based-sample-preparation/">Lab (r)evolution &#8211; Best practice for laser-based sample preparation</a> appeared first on <a rel="nofollow" href="https://3d-micromac.de">Laser Micromachining - 3D-Micromac AG</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
